Flame retardant grade: UL94V2
UL94V2 is a flame retardant grade in the vertical burning test standard for plastic materials (UL94) developed by the Underwriters Laboratories (UL) of the United States. It is mainly used to evaluate the flame retardant performance of materials under vertical burning conditions. The following is a detailed interpretation of UL94V2:
I. The core definition of UL94V2
In the UL94 vertical burning test, V2-grade materials must meet the following key requirements (for specimens with a thickness of ≥3.0mm, some thin materials can also be tested):
Burning time:
The specimen is subjected to two 10-second vertical burning tests (each time the lower end of the specimen is ignited with a flame). After each removal of the flame, the flaming burning time of the specimen shall not exceed 30 seconds;
The total flaming burning time of the two burning tests shall not exceed 60 seconds.
Drop requirements:
During the combustion process, the specimen may produce flaming drips (i.e. burning molten droplets);
However, the drips shall not ignite the absorbent cotton 300mm below (if ignited, it will not meet the standard).
No spread requirement:
The flame cannot spread to the clamping device at the top of the specimen (i.e. the combustion cannot burn from the bottom to the position where the specimen is fixed).