Core definition of UL94 V0 grade

Jul 17, 2025 Leave a message

Core definition of UL94 V0 grade (based on UL94 vertical burning test)
The UL94 standard evaluates the flame retardancy of plastic materials through the "vertical burning test". The V0 grade must meet the following strict requirements (the test object is a material specimen of specified size):
Burning time limit (core indicator)
The specimen is ignited with a flame twice for 10 seconds (the flame directly contacts the lower end of the specimen). After each removal of the flame:
The flaming burning time of the specimen is ≤10 seconds (that is, the flame extinguishes itself within 10 seconds);
The total flaming burning time of the two combustions is ≤30 seconds (the sum of the two does not exceed 30 seconds).
Additional requirements: Even if the specimen has "flameless combustion" (only burning, no open flame), the flameless combustion time each time must be ≤30 seconds, and the total flameless combustion time of the two combustions is ≤60 seconds.
No flame spread and dripping requirements
During the combustion process, the flame cannot spread to the clamping device at the top of the sample (that is, the flame cannot burn from the bottom to the position where the sample is fixed to avoid overall combustion);
"Flaming dripping" is absolutely prohibited: even if there are molten droplets falling during combustion, they must be cold droplets without flames (the absorbent cotton 300mm below cannot be ignited, otherwise it will directly fail to meet the standard).

Send Inquiry

whatsapp

Phone

E-mail

Inquiry